Telaire T6723-8K5 CO2 Alarm Modules are designed for heater applications requiring high limit controls. They are individually factory-calibrated to trigger Alarm Signal at 8500 ppm CO2, Ventilation Warning Signal at 7500 ppm CO2, and Low Battery Warning Signal (for applications using batteries). They are compliant with the latest NF128 LNE test protocol.
Features
- Designed specifically for the Original Equipment Manufacturers (OEM)
- Reliable design based on 25 years of infrared (IR) sensor manufacturing
- ROHS and WEEE compliant for European applications
- Protected by US Patents US6526801, US6255653, US6410918, and US6588250 (Patents Pending)
Specifications
General Specifications: | |
---|---|
Operating Temperature Range | -20°C to +55°C |
Storage Temperature Range | -20°C to +70°C |
Operating Humidity Range | 0-99% |
Sensor Life | Designed for 5 years of heater use with no calibration required |
Self-Diagnostics | Detector and lamp failures |
"Forced Alarm" Test Pad | Simulates warning and alarm shutdown through the sensor |
Electrical Specifications: | |
---|---|
Power Input | 4.3VDC – 7.0VDC |
Average Current @ 6.0 VDC |
|
Peak Current | < 100mA ± 10% |
Low Voltage Shutdown | 4.3 VDC ± 5% |
Connector Type | JST B5B-EH-A(LF) |